Received a set of three-way semiconductor silicon wafer handling robot, body 0190-52910, control cabinet 0190-46909.

           The customer said there was a collision and the cause could not be identified. After disassembling and inspecting the machine, and conducting power on testing, the chief maintenance technician found that the lock was abnormal due to a malfunction in the three-axis motor encoder and control cabinet communication board.